- A2L refrigerant
- A lower-GWP refrigerant class (e.g. R-32, R-454B) with mild flammability. Requires A2L-rated equipment, updated safety practices, and trained technicians.
- Acceptance testing
- Functional tests required by California's energy code (Title 24) to verify that installed mechanical systems operate as designed, performed by a certified technician and documented for the building department.
- AHJ (authority having jurisdiction)
- The government body that issues permits and enforces codes for a project, usually the local building department.
- AIM Act
- The American Innovation and Manufacturing Act, a federal law that phases down HFC production and use and supports emissions-reduction and reclamation requirements.
- Air handling unit (AHU)
- A central unit that conditions and circulates air through ductwork, containing fans, coils, filters, and dampers.
- Air-cooled condenser
- A condenser that rejects heat to outdoor air using fans, as opposed to water. Standard on rooftop units and most walk-in condensing units.
- Anode rod
- A sacrificial metal rod in a storage water heater that corrodes in place of the tank. When it is consumed, the tank begins to corrode.
- ASHRAE 188
- A standard that sets requirements for Legionellosis risk management in building water systems, including cooling towers and hot water.
- ASHRAE 90.1
- A national energy standard for commercial buildings, used by many states instead of or alongside local energy codes.
- Balancing (TAB)
- Testing, adjusting, and balancing: measuring and adjusting airflow or water flow so each space receives its design quantity.
- BAS / BMS
- Building automation system or building management system. A networked control system that schedules, monitors, and alarms HVAC and other building equipment.
- Bid bond
- A guarantee from a surety that the bidder will sign the contract and provide required bonds if awarded the project.
- Blowdown
- Water intentionally discharged from a boiler or cooling tower to control the concentration of dissolved solids.
- Capacitor (run / start)
- An electrical component that helps start or run motors and compressors. Weak capacitors are among the most common causes of no-cool calls.
- Certified payroll
- A payroll report, signed under penalty of perjury, showing each worker, classification, hours, and wages paid on a prevailing-wage project.
- Chilled water system
- A system in which a chiller cools water that is circulated to air handlers or fan coils instead of using refrigerant in distribution piping.
- Chiller
- A machine that removes heat from water using a refrigeration cycle. Air-cooled or water-cooled.
- Commissioning (Cx)
- A quality-assurance process that verifies a building's systems are installed and operate according to the design intent.
- Compressor
- The component that pressurizes refrigerant and circulates it through the system. Scroll, screw, reciprocating, and centrifugal types are common in commercial work.
- Condensate drain
- The pipe that removes water produced by cooling coils. A clogged drain is a leading cause of ceiling leaks.
- Condenser
- The coil where refrigerant rejects heat and turns from vapor to liquid.
- Condensing boiler
- A high-efficiency boiler that extracts heat from flue gases by condensing water vapor, requiring a condensate drain and low return-water temperatures.
- Condensing unit
- An outdoor assembly containing the compressor and condenser, used with walk-ins and split systems.
- Contactor
- An electrical switch that starts and stops compressors and fan motors. Contacts wear and pit over time.
- Curb adapter
- A fabricated adapter that lets a new rooftop unit fit an existing roof curb of a different size.
- DAS / DSA
- In California schools, the Division of the State Architect, which reviews and oversees K-12 and community college construction.
- Davis-Bacon Act
- A federal law requiring prevailing wages on covered federal construction contracts.
- Defrost cycle
- A scheduled process that melts frost from evaporator coils using electric heaters, hot refrigerant gas, or warm air.
- Delta-T (ΔT)
- The temperature difference across a coil, chiller, or heat exchanger. A key diagnostic measurement.
- Demand-control ventilation (DCV)
- A strategy that adjusts outdoor-air intake based on measured occupancy, typically using CO2 sensors.
- DIR registration
- Registration with California's Department of Industrial Relations, required for contractors and subcontractors on public works projects.
- Discharge pressure / head pressure
- The pressure on the high side of a refrigeration system, after the compressor. High head pressure often indicates a dirty condenser or failed fan.
- ECM motor
- An electronically commutated motor. Efficient, variable-speed motors increasingly used in evaporator and condenser fans.
- Economizer
- A set of dampers and controls that brings in cool outdoor air for free cooling when conditions allow.
- EER / SEER / IEER
- Efficiency ratings for cooling equipment. IEER (integrated energy efficiency ratio) is used for commercial equipment and reflects part-load operation.
- Evaporator
- The coil where refrigerant absorbs heat and evaporates, cooling the air or water passing over it.
- Expansion valve (TXV / EEV)
- A metering device that controls refrigerant flow into the evaporator. Thermostatic (TXV) and electronic (EEV) types.
- Fault detection and diagnostics (FDD)
- Built-in controls that identify equipment faults such as economizer failures or refrigerant problems.
- GWP (global warming potential)
- A measure of how much a refrigerant contributes to warming compared with carbon dioxide over a set period. Lower is better.
- Heat exchanger
- A surface that transfers heat between two media. In gas furnaces, a cracked heat exchanger is a safety hazard.
- HFC
- Hydrofluorocarbon refrigerants (e.g. R-410A, R-404A) that do not harm the ozone layer but have high GWP and are being phased down.
- Job order contract (JOC)
- A public contracting method using a unit-price book to issue repeated task orders.
- Latent load
- Cooling load associated with removing moisture from air, as opposed to sensible load which changes temperature.
- Legionella
- Bacteria that grow in warm water systems, including cooling towers and hot water systems, and can cause Legionnaires' disease.
- Line set
- The pair of refrigerant pipes connecting an outdoor unit to an indoor coil or evaporator.
- MERV
- Minimum efficiency reporting value, a rating of air filter effectiveness from 1 to 16.
- Miller Act
- A federal law requiring payment and performance bonds on federal construction contracts above a threshold.
- NAICS 238220
- North American Industry Classification code for plumbing, heating, and air-conditioning contractors, used in federal contracting.
- NOx
- Nitrogen oxides, air pollutants regulated by the South Coast AQMD for gas-fired water heaters and boilers.
- PLA (project labor agreement)
- A pre-hire collective bargaining agreement for a specific construction project that sets labor terms for all contractors on the job.
- PM (preventive maintenance)
- Scheduled inspection and service intended to prevent failures and extend equipment life.
- Prevailing wage
- The minimum hourly wage and benefits rate for a craft in a locality, required on covered public works.
- Reach-in
- A self-contained commercial refrigerator or freezer with doors the user reaches into, as opposed to walk-ins.
- Reclaim
- Processing used refrigerant to meet purity standards of new product, performed by an EPA-certified reclaimer.
- Recovery
- Removing refrigerant from equipment and storing it in an approved container, as required before repairs or disposal.
- Retention
- A percentage of each progress payment held back by the owner until project completion.
- RFI
- Request for information, a formal question from the contractor to the designer during a project.
- Rooftop unit (RTU)
- A self-contained packaged HVAC unit installed on a roof, containing cooling, heating, fans, and controls.
- Scroll compressor
- A compressor with two interleaved spiral elements, common in commercial rooftop units and refrigeration.
- Section 608
- The section of the Clean Air Act governing refrigerant handling, technician certification, recovery, and leak repair.
- Sensible load
- Cooling load associated with changing air temperature, as opposed to removing moisture.
- Static pressure
- The pressure in a duct system that resists airflow, measured in inches of water column. A diagnostic indicator of duct and filter conditions.
- Subcooling
- Cooling of liquid refrigerant below its condensing temperature. Used to evaluate refrigerant charge.
- Submittal
- Documentation of proposed equipment or materials submitted to the engineer for approval before purchase or installation.
- Suction pressure
- The pressure on the low side of a refrigeration system before the compressor.
- Superheat
- The temperature of refrigerant vapor above its boiling point at a given pressure. Used to evaluate evaporator feeding and charge.
- Title 20
- California appliance efficiency regulations applying to certain equipment sold in the state.
- Title 24
- California's Building Energy Efficiency Standards (Title 24, Part 6), which set efficiency and compliance requirements for new buildings and alterations.
- Tonnage
- A unit of cooling capacity. One ton equals 12,000 BTU per hour.
- UA Local 250
- A local union of the United Association of Plumbers, Pipefitters, Steamfitters, and Service Techs in Southern California.
- VAV (variable air volume)
- A system that varies the amount of conditioned air delivered to each zone to match load.
- VFD (variable frequency drive)
- An electronic controller that varies motor speed to match demand, saving energy on fans and pumps.
- Walk-in
- An insulated, room-size cooler or freezer served by a refrigeration system, typically with a remote or roof-mounted condensing unit.